Wheat & maize flour mills · 20–500 TPD · Complete lines and single machinesWhatsApp +86 155 3803 1104  ·  sales@farivomill.com
WhatsApp an engineer
Home / Products / Spouting & pipework / Two-way diverters

Two-way diverters

Two-way valves with inlet collar for gravity flow, sealed two-way valves for low-pressure pneumatic lines, and two-way distributors, manual, pneumatic or with cylinder.

24 product types370 sizes860 SKUs
Product types

Choose a type, then a size

Each type below lists every diameter with the wall thicknesses available in each finish. Quote by SKU, or send your own sizes and we make to them.

Two-way valves with inlet collar, symmetrical, hand-operated

Technical drawing — configuration shown.

TW01

Two-way valves with inlet collar, symmetrical, hand-operated

Type code: TW01. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
100α=60°; A=135; B=50; C=41; L1=118; L2=88; L3=602 mm2 mm
120α=60°; A=160; B=50; C=54; L1=129; L2=99; L3=602 mm2 mm
150α=60°; A=200; B=80; C=60; L1=146; L2=116; L3=602 / 3 mm2 mm
175α=60°; A=218; B=63; C=75; L1=159; L2=129; L3=602 / 3 mm2 mm
200α=60°; A=265; B=110; C=70; L1=178; L2=148; L3=602 / 3 mm2 mm
250α=60°; A=305; B=115; C=82; L1=199; L2=169; L3=602 / 3 mm2 mm
300α=60°; A=385; B=145; C=110; L1=225; L2=195; L3=602 / 3 mm2 mm
350α=50°; A=520; B=95; C=185; L1=345; L2=300; L3=902 / 3 mm2 mm
400α=50°; A=580; B=105; C=195; L1=378; L2=333; L3=902 / 3 mm2 mm
Two-way valves with inlet collar, symmetrical, fitted with pneumatic rotary actuator
TW02

Two-way valves with inlet collar, symmetrical, fitted with pneumatic rotary actuator

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches
  • Completely wired in limit switch box

Type code: TW02. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=135; B=50; C=41; E=215; L1=129; L2=88; L3=2972 mm2 mm
100230 V ACα=60°; A=135; B=50; C=41; E=215; L1=129; L2=88; L3=2972 mm2 mm
12024 V DCα=60°; A=160; B=50; C=54; E=215; L1=129; L2=99; L3=2972 mm2 mm
120230 V ACα=60°; A=160; B=50; C=54; E=215; L1=129; L2=99; L3=2972 mm2 mm
15024 V DCα=60°; A=200; B=80; C=60; E=215; L1=146; L2=116; L3=2972 / 3 mm2 mm
150230 V ACα=60°; A=200; B=80; C=60; E=215; L1=146; L2=116; L3=2972 / 3 mm2 mm
17524 V DCα=60°; A=218; B=63; C=75; E=215; L1=159; L2=129; L3=2972 / 3 mm2 mm
175230 V ACα=60°; A=218; B=63; C=75; E=215; L1=159; L2=129; L3=2972 / 3 mm2 mm
20024 V DCα=60°; A=265; B=110; C=70; E=290; L1=178; L2=148; L3=3022 / 3 mm2 mm
200230 V ACα=60°; A=265; B=110; C=70; E=290; L1=178; L2=148; L3=3022 / 3 mm2 mm
25024 V DCα=60°; A=305; B=115; C=82; E=290; L1=199; L2=169; L3=3022 / 3 mm2 mm
250230 V ACα=60°; A=305; B=115; C=82; E=290; L1=199; L2=169; L3=3022 / 3 mm2 mm
30024 V DCα=60°; A=385; B=145; C=110; E=290; L1=225; L2=195; L3=3022 / 3 mm2 mm
300230 V ACα=60°; A=385; B=145; C=110; E=290; L1=225; L2=195; L3=3022 / 3 mm2 mm
35024 V DCα=50°; A=520; B=95; C=185; E=310; L1=345; L2=300; L3=3122 / 3 mm2 mm
350230 V ACα=50°; A=520; B=95; C=185; E=310; L1=345; L2=300; L3=3122 / 3 mm2 mm
40024 V DCα=50°; A=580; B=105; C=195; E=310; L1=378; L2=333; L3=3122 / 3 mm2 mm
400230 V ACα=50°; A=580; B=105; C=195; E=310; L1=378; L2=333; L3=3122 / 3 mm2 mm
Two-way valves with inlet collar, symmetrical, fitted with cylinder
TW03

Two-way valves with inlet collar, symmetrical, fitted with cylinder

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches on the cylinder

Type code: TW03. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=135; B=56; C=41; E=440; L1=129; L2=88; L3=882 mm2 mm
100230 V ACα=60°; A=135; B=56; C=41; E=440; L1=129; L2=88; L3=882 mm2 mm
12024 V DCα=60°; A=160; B=50; C=54; E=440; L1=129; L2=99; L3=882 mm2 mm
120230 V ACα=60°; A=160; B=50; C=54; E=440; L1=129; L2=99; L3=882 mm2 mm
15024 V DCα=60°; A=200; B=80; C=60; E=440; L1=146; L2=116; L3=882 / 3 mm2 mm
150230 V ACα=60°; A=200; B=80; C=60; E=440; L1=146; L2=116; L3=882 / 3 mm2 mm
17524 V DCα=60°; A=218; B=63; C=75; E=440; L1=159; L2=129; L3=882 / 3 mm2 mm
175230 V ACα=60°; A=218; B=63; C=75; E=440; L1=159; L2=129; L3=882 / 3 mm2 mm
20024 V DCα=60°; A=265; B=110; C=70; E=470; L1=178; L2=148; L3=882 / 3 mm2 mm
200230 V ACα=60°; A=265; B=110; C=70; E=470; L1=178; L2=148; L3=882 / 3 mm2 mm
25024 V DCα=60°; A=305; B=115; C=82; E=470; L1=199; L2=169; L3=882 / 3 mm2 mm
250230 V ACα=60°; A=305; B=115; C=82; E=470; L1=199; L2=169; L3=882 / 3 mm2 mm
30024 V DCα=60°; A=385; B=145; C=110; E=470; L1=225; L2=195; L3=882 / 3 mm2 mm
300230 V ACα=60°; A=385; B=145; C=110; E=470; L1=225; L2=195; L3=882 / 3 mm2 mm
35024 V DCα=50°; A=520; B=95; C=185; E=470; L1=345; L2=300; L3=902 / 3 mm2 mm
350230 V ACα=50°; A=520; B=95; C=185; E=470; L1=345; L2=300; L3=902 / 3 mm2 mm
40024 V DCα=50°; A=580; B=105; C=195; E=470; L1=378; L2=333; L3=902 / 3 mm2 mm
400230 V ACα=50°; A=580; B=105; C=195; E=470; L1=378; L2=333; L3=902 / 3 mm2 mm
Two-way valves with inlet collar, asymmetrical, hand-operated

Technical drawing — configuration shown.

TW04

Two-way valves with inlet collar, asymmetrical, hand-operated

  • Standard version: Right-side mounting

Type code: TW04. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
100α=60°; A=135; B=65; C=41; F=200; L1=118; L2=88; L3=602 mm2 mm
120α=60°; A=160; B=70; C=54; F=230; L1=129; L2=99; L3=602 mm2 mm
150α=60°; A=200; B=100; C=60; F=300; L1=146; L2=116; L3=602 / 3 mm2 mm
175α=60°; A=218; B=90; C=75; F=308; L1=159; L2=129; L3=602 / 3 mm2 mm
200α=60°; A=265; B=145; C=70; F=410; L1=178; L2=148; L3=602 / 3 mm2 mm
250α=60°; A=305; B=155; C=82; F=460; L1=199; L2=169; L3=602 / 3 mm2 mm
300α=60°; A=385; B=190; C=110; F=575; L1=225; L2=195; L3=602 / 3 mm2 mm
350α=50°; A=520; B=150; C=185; F=670; L1=345; L2=300; L3=902 / 3 mm2 mm
400α=50°; A=580; B=170; C=195; F=750; L1=378; L2=333; L3=902 / 3 mm2 mm
Two-way valves with inlet collar, asymmetrical, fitted with pneumatic rotary actuator
TW05

Two-way valves with inlet collar, asymmetrical, fitted with pneumatic rotary actuator

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches
  • Standard version: Right-side mounting
  • Completely wired in limit switch box

Type code: TW05. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=135; B=65; C=41; E=252; F=200; L1=82; L2=88; L3=2822 mm2 mm
100230 V ACα=60°; A=135; B=65; C=41; E=252; F=200; L1=82; L2=88; L3=2822 mm2 mm
12024 V DCα=60°; A=160; B=70; C=54; E=252; F=230; L1=90; L2=99; L3=2822 mm2 mm
120230 V ACα=60°; A=160; B=70; C=54; E=252; F=230; L1=90; L2=99; L3=2822 mm2 mm
15024 V DCα=60°; A=200; B=100; C=60; E=252; F=300; L1=146; L2=116; L3=2822 / 3 mm2 mm
150230 V ACα=60°; A=200; B=100; C=60; E=252; F=300; L1=146; L2=116; L3=2822 / 3 mm2 mm
17524 V DCα=60°; A=218; B=90; C=75; E=252; F=308; L1=159; L2=129; L3=2822 / 3 mm2 mm
175230 V ACα=60°; A=218; B=90; C=75; E=252; F=308; L1=159; L2=129; L3=2822 / 3 mm2 mm
20024 V DCα=60°; A=265; B=145; C=70; E=308; F=410; L1=178; L2=148; L3=3022 / 3 mm2 mm
200230 V ACα=60°; A=265; B=145; C=70; E=308; F=410; L1=178; L2=148; L3=3022 / 3 mm2 mm
25024 V DCα=60°; A=305; B=156; C=82; E=308; F=460; L1=199; L2=169; L3=3022 / 3 mm2 mm
250230 V ACα=60°; A=305; B=156; C=82; E=308; F=460; L1=199; L2=169; L3=3022 / 3 mm2 mm
30024 V DCα=60°; A=385; B=190; C=110; E=308; F=575; L1=225; L2=195; L3=3022 / 3 mm2 mm
300230 V ACα=60°; A=385; B=190; C=110; E=308; F=575; L1=225; L2=195; L3=3022 / 3 mm2 mm
35024 V DCα=50°; A=520; B=150; C=185; E=342; F=670; L1=325; L2=300; L3=3342 / 3 mm2 mm
350230 V ACα=50°; A=520; B=150; C=185; E=342; F=670; L1=325; L2=300; L3=3342 / 3 mm2 mm
40024 V DCα=50°; A=580; B=170; C=195; E=342; F=750; L1=350; L2=333; L3=3342 / 3 mm2 mm
400230 V ACα=50°; A=580; B=170; C=195; E=342; F=750; L1=350; L2=333; L3=3342 / 3 mm2 mm
Two-way valves with inlet collar, asymmetrical, fitted with cylinder
TW06

Two-way valves with inlet collar, asymmetrical, fitted with cylinder

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches on the cylinder
  • Standard version: Right-side mounting

Type code: TW06. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=135; B=65; C=41; E=440; F=200; L1=82; L2=88; L3=882 mm2 mm
100230 V ACα=60°; A=135; B=65; C=41; E=440; F=200; L1=82; L2=88; L3=882 mm2 mm
12024 V DCα=60°; A=160; B=70; C=54; E=440; F=230; L1=90; L2=99; L3=882 mm2 mm
120230 V ACα=60°; A=160; B=70; C=54; E=440; F=230; L1=90; L2=99; L3=882 mm2 mm
15024 V DCα=60°; A=200; B=100; C=60; E=440; F=300; L1=146; L2=116; L3=882 / 3 mm2 mm
150230 V ACα=60°; A=200; B=100; C=60; E=440; F=300; L1=146; L2=116; L3=882 / 3 mm2 mm
17524 V DCα=60°; A=218; B=90; C=75; E=440; F=308; L1=159; L2=129; L3=882 / 3 mm2 mm
175230 V ACα=60°; A=218; B=90; C=75; E=440; F=308; L1=159; L2=129; L3=882 / 3 mm2 mm
20024 V DCα=60°; A=265; B=145; C=70; E=470; F=410; L1=178; L2=148; L3=882 / 3 mm2 mm
200230 V ACα=60°; A=265; B=145; C=70; E=470; F=410; L1=178; L2=148; L3=882 / 3 mm2 mm
25024 V DCα=60°; A=305; B=156; C=82; E=470; F=460; L1=199; L2=169; L3=882 / 3 mm2 mm
250230 V ACα=60°; A=305; B=156; C=82; E=470; F=460; L1=199; L2=169; L3=882 / 3 mm2 mm
30024 V DCα=60°; A=385; B=190; C=110; E=470; F=575; L1=225; L2=195; L3=882 / 3 mm2 mm
300230 V ACα=60°; A=385; B=190; C=110; E=470; F=575; L1=225; L2=195; L3=882 / 3 mm2 mm
35024 V DCα=50°; A=520; B=150; C=185; E=470; F=670; L1=325; L2=300; L3=902 / 3 mm2 mm
350230 V ACα=50°; A=520; B=150; C=185; E=470; F=670; L1=325; L2=300; L3=902 / 3 mm2 mm
40024 V DCα=50°; A=580; B=170; C=195; E=470; F=750; L1=350; L2=333; L3=902 / 3 mm2 mm
400230 V ACα=50°; A=580; B=170; C=195; E=470; F=750; L1=350; L2=333; L3=902 / 3 mm2 mm
Two-way valves with seal, symmetrical, hand-operated

Technical drawing — configuration shown.

TW07

Two-way valves with seal, symmetrical, hand-operated

Type code: TW07. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
100α=60°; A=135; B=50; C=87; L1=140; L2=88; L3=882 mm2 mm
120α=60°; A=160; B=50; C=112; L1=148; L2=96; L3=882 mm2 mm
150α=60°; A=200; B=80; C=136; L1=168; L2=119; L3=882 / 3 mm2 mm
175α=60°; A=218; B=63; C=170; L1=198; L2=147; L3=882 / 3 mm2 mm
200α=60°; A=265; B=110; C=167; L1=199; L2=150; L3=882 / 3 mm2 mm
250α=60°; A=305; B=115; C=215; L1=220; L2=171; L3=882 / 3 mm2 mm
300α=60°; A=385; B=145; C=260; L1=264; L2=213; L3=882 / 3 mm2 mm
Two-way valves with seal, symmetrical, fitted with pneumatic rotary actuator
TW08

Two-way valves with seal, symmetrical, fitted with pneumatic rotary actuator

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches
  • Completely wired in limit switch box

Type code: TW08. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=135; B=50; C=87; E=193; L1=140; L2=110; L3=2652 mm2 mm
100230 V ACα=60°; A=135; B=50; C=87; E=193; L1=140; L2=110; L3=2652 mm2 mm
12024 V DCα=60°; A=160; B=50; C=112; E=193; L1=148; L2=118; L3=2652 mm2 mm
120230 V ACα=60°; A=160; B=50; C=112; E=193; L1=148; L2=118; L3=2652 mm2 mm
15024 V DCα=60°; A=200; B=80; C=136; E=193; L1=168; L2=138; L3=2652 / 3 mm2 mm
150230 V ACα=60°; A=200; B=80; C=136; E=193; L1=168; L2=138; L3=2652 / 3 mm2 mm
17524 V DCα=60°; A=218; B=63; C=170; E=193; L1=198; L2=168; L3=2652 / 3 mm2 mm
175230 V ACα=60°; A=218; B=63; C=170; E=193; L1=198; L2=168; L3=2652 / 3 mm2 mm
20024 V DCα=60°; A=265; B=110; C=167; E=225; L1=199; L2=169; L3=2752 / 3 mm2 mm
200230 V ACα=60°; A=265; B=110; C=167; E=225; L1=199; L2=169; L3=2752 / 3 mm2 mm
25024 V DCα=60°; A=305; B=115; C=215; E=225; L1=220; L2=190; L3=2752 / 3 mm2 mm
250230 V ACα=60°; A=305; B=115; C=215; E=225; L1=220; L2=190; L3=2752 / 3 mm2 mm
30024 V DCα=60°; A=385; B=145; C=260; E=225; L1=264; L2=234; L3=2752 / 3 mm2 mm
300230 V ACα=60°; A=385; B=145; C=260; E=225; L1=264; L2=234; L3=2752 / 3 mm2 mm
Two-way valves with seal, symmetrical, fitted with cylinder
TW09

Two-way valves with seal, symmetrical, fitted with cylinder

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches on the cylinder

Type code: TW09. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=135; B=50; C=87; E=440; L1=140; L2=110; L3=882 mm2 mm
100230 V ACα=60°; A=135; B=50; C=87; E=440; L1=140; L2=110; L3=882 mm2 mm
12024 V DCα=60°; A=160; B=50; C=112; E=440; L1=148; L2=118; L3=882 mm2 mm
120230 V ACα=60°; A=160; B=50; C=112; E=440; L1=148; L2=118; L3=882 mm2 mm
15024 V DCα=60°; A=200; B=80; C=136; E=440; L1=168; L2=138; L3=882 / 3 mm2 mm
150230 V ACα=60°; A=200; B=80; C=136; E=440; L1=168; L2=138; L3=882 / 3 mm2 mm
17524 V DCα=60°; A=218; B=63; C=170; E=440; L1=198; L2=168; L3=882 / 3 mm2 mm
175230 V ACα=60°; A=218; B=63; C=170; E=440; L1=198; L2=168; L3=882 / 3 mm2 mm
20024 V DCα=60°; A=265; B=110; C=167; E=470; L1=199; L2=169; L3=882 / 3 mm2 mm
200230 V ACα=60°; A=265; B=110; C=167; E=470; L1=199; L2=169; L3=882 / 3 mm2 mm
25024 V DCα=60°; A=305; B=115; C=215; E=470; L1=220; L2=190; L3=882 / 3 mm2 mm
250230 V ACα=60°; A=305; B=115; C=215; E=470; L1=220; L2=190; L3=882 / 3 mm2 mm
30024 V DCα=60°; A=385; B=145; C=260; E=470; L1=264; L2=234; L3=882 / 3 mm2 mm
300230 V ACα=60°; A=385; B=145; C=260; E=470; L1=264; L2=234; L3=882 / 3 mm2 mm
Two-way valves with seal, asymmetrical, hand-operated

Technical drawing — configuration shown.

TW10

Two-way valves with seal, asymmetrical, hand-operated

  • Standard version: Right-side mounting

Type code: TW10. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
100α=60°; A=135; B=65; C=87; F=200; L1=140; L2=88; L3=882 mm2 mm
120α=60°; A=160; B=70; C=112; F=230; L1=148; L2=96; L3=882 mm2 mm
150α=60°; A=200; B=100; C=136; F=300; L1=168; L2=119; L3=882 / 3 mm2 mm
175α=60°; A=218; B=90; C=170; F=308; L1=198; L2=149; L3=882 / 3 mm2 mm
200α=60°; A=265; B=145; C=167; F=410; L1=199; L2=150; L3=882 / 3 mm2 mm
250α=60°; A=305; B=155; C=215; F=460; L1=220; L2=171; L3=882 / 3 mm2 mm
300α=60°; A=385; B=190; C=260; F=575; L1=264; L2=197; L3=882 / 3 mm2 mm
Two-way valves with seal, asymmetrical, fitted with pneumatic rotary actuator
TW11

Two-way valves with seal, asymmetrical, fitted with pneumatic rotary actuator

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches
  • Completely wired in limit switch box
  • Standard version: Right-side mounting

Type code: TW11. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=135; B=65; C=87; E=193; F=200; L1=140; L2=110; L3=2652 mm2 mm
100230 V ACα=60°; A=135; B=65; C=87; E=193; F=200; L1=140; L2=110; L3=2652 mm2 mm
12024 V DCα=60°; A=160; B=70; C=112; E=193; F=230; L1=148; L2=118; L3=2652 mm2 mm
120230 V ACα=60°; A=160; B=70; C=112; E=193; F=230; L1=148; L2=118; L3=2652 mm2 mm
15024 V DCα=60°; A=200; B=100; C=136; E=193; F=300; L1=168; L2=138; L3=2652 / 3 mm2 mm
150230 V ACα=60°; A=200; B=100; C=136; E=193; F=300; L1=168; L2=138; L3=2652 / 3 mm2 mm
17524 V DCα=60°; A=218; B=90; C=170; E=193; F=308; L1=198; L2=168; L3=2752 / 3 mm2 mm
175230 V ACα=60°; A=218; B=90; C=170; E=193; F=308; L1=198; L2=168; L3=2752 / 3 mm2 mm
20024 V DCα=60°; A=265; B=145; C=167; E=225; F=410; L1=199; L2=169; L3=2752 / 3 mm2 mm
200230 V ACα=60°; A=265; B=145; C=167; E=225; F=410; L1=199; L2=169; L3=2752 / 3 mm2 mm
25024 V DCα=60°; A=305; B=155; C=215; E=225; F=460; L1=220; L2=190; L3=2752 / 3 mm2 mm
250230 V ACα=60°; A=305; B=155; C=215; E=225; F=460; L1=220; L2=190; L3=2752 / 3 mm2 mm
30024 V DCα=60°; A=385; B=190; C=260; E=225; F=575; L1=264; L2=234; L3=2752 / 3 mm2 mm
300230 V ACα=60°; A=385; B=190; C=260; E=225; F=575; L1=264; L2=234; L3=2752 / 3 mm2 mm
Two-way valves with seal, asymmetrical, fitted with cylinder
TW12

Two-way valves with seal, asymmetrical, fitted with cylinder

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches on the cylinder
  • Standard version: Right-side mounting

Type code: TW12. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=135; B=65; C=87; E=440; F=200; L1=140; L2=110; L3=882 mm2 mm
100230 V ACα=60°; A=135; B=65; C=87; E=440; F=200; L1=140; L2=110; L3=882 mm2 mm
12024 V DCα=60°; A=160; B=70; C=112; E=440; F=230; L1=148; L2=118; L3=882 mm2 mm
120230 V ACα=60°; A=160; B=70; C=112; E=440; F=230; L1=148; L2=118; L3=882 mm2 mm
15024 V DCα=60°; A=200; B=100; C=136; E=440; F=300; L1=168; L2=138; L3=882 / 3 mm2 mm
150230 V ACα=60°; A=200; B=100; C=136; E=440; F=300; L1=168; L2=138; L3=882 / 3 mm2 mm
17524 V DCα=60°; A=218; B=90; C=170; E=440; F=308; L1=198; L2=168; L3=882 / 3 mm2 mm
175230 V ACα=60°; A=218; B=90; C=170; E=440; F=308; L1=198; L2=168; L3=882 / 3 mm2 mm
20024 V DCα=60°; A=265; B=145; C=167; E=470; F=410; L1=199; L2=169; L3=882 / 3 mm2 mm
200230 V ACα=60°; A=265; B=145; C=167; E=470; F=410; L1=199; L2=169; L3=882 / 3 mm2 mm
25024 V DCα=60°; A=305; B=155; C=215; E=470; F=460; L1=220; L2=190; L3=882 / 3 mm2 mm
250230 V ACα=60°; A=305; B=155; C=215; E=470; F=460; L1=220; L2=190; L3=882 / 3 mm2 mm
30024 V DCα=60°; A=385; B=190; C=260; E=470; F=575; L1=264; L2=234; L3=882 / 3 mm2 mm
300230 V ACα=60°; A=385; B=190; C=260; E=470; F=575; L1=264; L2=234; L3=882 / 3 mm2 mm
Two-way distributors 60°, symmetrical, hand-operated
TW13

Two-way distributors 60°, symmetrical, hand-operated

  • The use of pneumatic actuators is recommended as they hold the inner flap better in the end position
  • Shaft and inner flap with seal

Type code: TW13. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
100α=60°; A=220; B=65; C=128; L1=117; L2=82; L3=752 mm2 mm
120α=60°; A=240; B=70; C=145; L1=127; L2=92; L3=752 mm2 mm
150α=60°; A=250; B=75; C=168; L1=142; L2=107; L3=752 mm2 mm
200α=60°; A=300; B=105; C=218; L1=164; L2=132; L3=752 mm2 mm
250α=60°; A=370; B=130; C=277; L1=205; L2=160; L3=752 mm2 mm
300α=60°; A=435; B=150; C=326; L1=230; L2=185; L3=752 mm2 mm
Two-way distributors 60°, symmetrical, fitted with pneumatic rotary actuator
TW14

Two-way distributors 60°, symmetrical, fitted with pneumatic rotary actuator

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches
  • Completely wired in limit switch box
  • Shaft and inner flap with seal
  • DN > 300 mm with welded flanges

Type code: TW14. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=220; B=65; C=128; E=193; L1=117; L2=82; L3=2652 mm2 mm
100230 V ACα=60°; A=220; B=65; C=128; E=193; L1=117; L2=82; L3=2652 mm2 mm
12024 V DCα=60°; A=240; B=70; C=145; E=193; L1=127; L2=92; L3=2652 mm2 mm
120230 V ACα=60°; A=240; B=70; C=145; E=193; L1=127; L2=92; L3=2652 mm2 mm
15024 V DCα=60°; A=250; B=75; C=168; E=193; L1=142; L2=107; L3=3022 mm2 mm
150230 V ACα=60°; A=250; B=75; C=168; E=193; L1=142; L2=107; L3=3022 mm2 mm
20024 V DCα=60°; A=300; B=105; C=218; E=225; L1=164; L2=132; L3=3112 mm2 mm
200230 V ACα=60°; A=300; B=105; C=218; E=225; L1=164; L2=132; L3=3112 mm2 mm
25024 V DCα=60°; A=370; B=130; C=277; E=271; L1=205; L2=160; L3=3342 mm2 mm
250230 V ACα=60°; A=370; B=130; C=277; E=271; L1=205; L2=160; L3=3342 mm2 mm
30024 V DCα=60°; A=435; B=150; C=326; E=271; L1=230; L2=185; L3=3342 mm2 mm
300230 V ACα=60°; A=435; B=150; C=326; E=271; L1=230; L2=185; L3=3342 mm2 mm
35024 V DCα=60°; A=500; B=185; C=377; E=402; L1=255; L2=210; L3=3542 mm2 mm
350230 V ACα=60°; A=500; B=185; C=377; E=402; L1=255; L2=210; L3=3542 mm2 mm
40024 V DCα=60°; A=600; B=205; C=427; E=402; L1=280; L2=235; L3=3542 mm2 mm
400230 V ACα=60°; A=600; B=205; C=427; E=402; L1=280; L2=235; L3=3542 mm2 mm
45024 V DCα=60°; A=650; B=225; C=474; E=486; L1=301; L2=261; L3=3923 mm3 mm
450230 V ACα=60°; A=650; B=225; C=474; E=486; L1=301; L2=261; L3=3923 mm3 mm
50024 V DCα=60°; A=700; B=250; C=574; E=486; L1=326; L2=286; L3=3923 mm3 mm
500230 V ACα=60°; A=700; B=250; C=574; E=486; L1=326; L2=286; L3=3923 mm3 mm
56024 V DCα=60°; A=800; B=300; C=592; E=486; L1=437; L2=357; L3=3923 mm3 mm
560230 V ACα=60°; A=800; B=300; C=592; E=486; L1=437; L2=357; L3=3923 mm3 mm
63024 V DCα=60°; A=900; B=350; C=662; E=486; L1=472; L2=392; L3=3923 mm3 mm
630230 V ACα=60°; A=900; B=350; C=662; E=486; L1=472; L2=392; L3=3923 mm3 mm
Two-way distributors 60°, symmetrical, fitted with cylinder
TW15

Two-way distributors 60°, symmetrical, fitted with cylinder

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches on the cylinder
  • Shaft and inner flap with seal
  • DN > 300 mm with welded flanges

Type code: TW15. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=220; B=65; C=128; E=440; L1=117; L2=82; L3=882 mm2 mm
100230 V ACα=60°; A=220; B=65; C=128; E=440; L1=117; L2=82; L3=882 mm2 mm
12024 V DCα=60°; A=240; B=70; C=145; E=440; L1=127; L2=92; L3=882 mm2 mm
120230 V ACα=60°; A=240; B=70; C=145; E=440; L1=127; L2=92; L3=882 mm2 mm
15024 V DCα=60°; A=250; B=75; C=168; E=470; L1=142; L2=107; L3=882 mm2 mm
150230 V ACα=60°; A=250; B=75; C=168; E=470; L1=142; L2=107; L3=882 mm2 mm
20024 V DCα=60°; A=300; B=105; C=218; E=470; L1=164; L2=132; L3=882 mm2 mm
200230 V ACα=60°; A=300; B=105; C=218; E=470; L1=164; L2=132; L3=882 mm2 mm
25024 V DCα=60°; A=370; B=130; C=277; E=470; L1=205; L2=160; L3=902 mm2 mm
250230 V ACα=60°; A=370; B=130; C=277; E=470; L1=205; L2=160; L3=902 mm2 mm
30024 V DCα=60°; A=435; B=150; C=326; E=470; L1=230; L2=185; L3=902 mm2 mm
300230 V ACα=60°; A=435; B=150; C=326; E=470; L1=230; L2=185; L3=902 mm2 mm
35024 V DCα=60°; A=500; B=185; C=377; E=490; L1=255; L2=210; L3=1102 mm2 mm
350230 V ACα=60°; A=500; B=185; C=377; E=490; L1=255; L2=210; L3=1102 mm2 mm
40024 V DCα=60°; A=600; B=205; C=427; E=490; L1=280; L2=235; L3=1102 mm2 mm
400230 V ACα=60°; A=600; B=205; C=427; E=490; L1=280; L2=235; L3=1102 mm2 mm
45024 V DCα=60°; A=650; B=225; C=474; E=540; L1=301; L2=261; L3=1103 mm3 mm
450230 V ACα=60°; A=650; B=225; C=474; E=540; L1=301; L2=261; L3=1103 mm3 mm
50024 V DCα=60°; A=700; B=250; C=574; E=540; L1=326; L2=286; L3=1103 mm3 mm
500230 V ACα=60°; A=700; B=250; C=574; E=540; L1=326; L2=286; L3=1103 mm3 mm
56024 V DCα=60°; A=800; B=300; C=592; E=540; L1=437; L2=357; L3=1103 mm3 mm
560230 V ACα=60°; A=800; B=300; C=592; E=540; L1=437; L2=357; L3=1103 mm3 mm
63024 V DCα=60°; A=900; B=350; C=662; E=540; L1=472; L2=392; L3=1103 mm3 mm
630230 V ACα=60°; A=900; B=350; C=662; E=540; L1=472; L2=392; L3=1103 mm3 mm
Two-way distributors 60°, asymmetrical, hand-operated
TW16

Two-way distributors 60°, asymmetrical, hand-operated

  • Standard version: Right-side mounting
  • The use of pneumatic actuators is recommended as they hold the inner flap better in the end position
  • Shaft and inner flap with seal

Type code: TW16. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
100α=60°; A=220; B=100; C=128; F=320; L1=117; L2=82; L3=752 mm2 mm
120α=60°; A=240; B=110; C=145; F=350; L1=127; L2=92; L3=752 mm2 mm
150α=60°; A=250; B=115; C=168; F=365; L1=142; L2=107; L3=752 mm2 mm
200α=60°; A=300; B=140; C=218; F=440; L1=164; L2=132; L3=752 mm2 mm
250α=60°; A=370; B=170; C=277; F=540; L1=205; L2=160; L3=752 mm2 mm
300α=60°; A=435; B=200; C=326; F=635; L1=230; L2=185; L3=752 mm2 mm
Two-way distributors 60°, asymmetrical, fitted with pneumatic rotary actuator
TW17

Two-way distributors 60°, asymmetrical, fitted with pneumatic rotary actuator

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches
  • Completely wired in limit switch box
  • Standard version: Right-side mounting
  • Shaft and inner flap with seal
  • DN > 300 mm with welded flanges

Type code: TW17. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=220; B=100; C=128; E=193; F=320; L1=117; L2=82; L3=2652 mm2 mm
100230 V ACα=60°; A=220; B=100; C=128; E=193; F=320; L1=117; L2=82; L3=2652 mm2 mm
12024 V DCα=60°; A=240; B=110; C=145; E=193; F=350; L1=127; L2=92; L3=2652 mm2 mm
120230 V ACα=60°; A=240; B=110; C=145; E=193; F=350; L1=127; L2=92; L3=2652 mm2 mm
15024 V DCα=60°; A=250; B=115; C=168; E=193; F=365; L1=142; L2=107; L3=3022 mm2 mm
150230 V ACα=60°; A=250; B=115; C=168; E=193; F=365; L1=142; L2=107; L3=3022 mm2 mm
20024 V DCα=60°; A=300; B=140; C=218; E=225; F=440; L1=164; L2=132; L3=3112 mm2 mm
200230 V ACα=60°; A=300; B=140; C=218; E=225; F=440; L1=164; L2=132; L3=3112 mm2 mm
25024 V DCα=60°; A=370; B=170; C=277; E=271; F=540; L1=205; L2=160; L3=3342 mm2 mm
250230 V ACα=60°; A=370; B=170; C=277; E=271; F=540; L1=205; L2=160; L3=3342 mm2 mm
30024 V DCα=60°; A=435; B=200; C=326; E=271; F=635; L1=230; L2=185; L3=3342 mm2 mm
300230 V ACα=60°; A=435; B=200; C=326; E=271; F=635; L1=230; L2=185; L3=3342 mm2 mm
35024 V DCα=60°; A=500; B=230; C=377; E=402; F=730; L1=255; L2=210; L3=3542 mm2 mm
350230 V ACα=60°; A=500; B=230; C=377; E=402; F=730; L1=255; L2=210; L3=3542 mm2 mm
40024 V DCα=60°; A=600; B=250; C=427; E=402; F=850; L1=280; L2=235; L3=3542 mm2 mm
400230 V ACα=60°; A=600; B=250; C=427; E=402; F=850; L1=280; L2=235; L3=3542 mm2 mm
45024 V DCα=60°; A=650; B=270; C=474; E=486; F=920; L1=301; L2=256; L3=3923 mm3 mm
450230 V ACα=60°; A=650; B=270; C=474; E=486; F=920; L1=301; L2=256; L3=3923 mm3 mm
50024 V DCα=60°; A=700; B=300; C=542; E=486; F=1000; L1=326; L2=288; L3=3923 mm3 mm
500230 V ACα=60°; A=700; B=300; C=542; E=486; F=1000; L1=326; L2=288; L3=3923 mm3 mm
56024 V DCα=60°; A=800; B=350; C=592; E=486; F=1150; L1=437; L2=357; L3=3923 mm3 mm
560230 V ACα=60°; A=800; B=350; C=592; E=486; F=1150; L1=437; L2=357; L3=3923 mm3 mm
63024 V DCα=60°; A=900; B=400; C=662; E=486; F=1300; L1=472; L2=392; L3=3923 mm3 mm
630230 V ACα=60°; A=900; B=400; C=662; E=486; F=1300; L1=472; L2=392; L3=3923 mm3 mm
Two-way distributors 60°, asymmetrical, fitted with cylinder
TW18

Two-way distributors 60°, asymmetrical, fitted with cylinder

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches on the cylinder
  • Standard version: Right-side mounting
  • Shaft and inner flap with seal
  • DN > 300 mm with welded flanges

Type code: TW18. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=60°; A=220; B=100; C=128; E=440; F=320; L1=117; L2=82; L3=882 mm2 mm
100230 V ACα=60°; A=220; B=100; C=128; E=440; F=320; L1=117; L2=82; L3=882 mm2 mm
12024 V DCα=60°; A=240; B=110; C=145; E=440; F=350; L1=127; L2=92; L3=882 mm2 mm
120230 V ACα=60°; A=240; B=110; C=145; E=440; F=350; L1=127; L2=92; L3=882 mm2 mm
15024 V DCα=60°; A=250; B=115; C=168; E=470; F=365; L1=142; L2=107; L3=882 mm2 mm
150230 V ACα=60°; A=250; B=115; C=168; E=470; F=365; L1=142; L2=107; L3=882 mm2 mm
20024 V DCα=60°; A=300; B=140; C=218; E=470; F=440; L1=164; L2=132; L3=882 mm2 mm
200230 V ACα=60°; A=300; B=140; C=218; E=470; F=440; L1=164; L2=132; L3=882 mm2 mm
25024 V DCα=60°; A=370; B=170; C=277; E=470; F=540; L1=205; L2=160; L3=902 mm2 mm
250230 V ACα=60°; A=370; B=170; C=277; E=470; F=540; L1=205; L2=160; L3=902 mm2 mm
30024 V DCα=60°; A=435; B=200; C=326; E=470; F=635; L1=230; L2=185; L3=902 mm2 mm
300230 V ACα=60°; A=435; B=200; C=326; E=470; F=635; L1=230; L2=185; L3=902 mm2 mm
35024 V DCα=60°; A=500; B=230; C=377; E=490; F=730; L1=255; L2=210; L3=1102 mm2 mm
350230 V ACα=60°; A=500; B=230; C=377; E=490; F=730; L1=255; L2=210; L3=1102 mm2 mm
40024 V DCα=60°; A=600; B=250; C=427; E=490; F=850; L1=280; L2=235; L3=1102 mm2 mm
400230 V ACα=60°; A=600; B=250; C=427; E=490; F=850; L1=280; L2=235; L3=1102 mm2 mm
45024 V DCα=60°; A=650; B=270; C=474; E=540; F=920; L1=301; L2=256; L3=1103 mm3 mm
450230 V ACα=60°; A=650; B=270; C=474; E=540; F=920; L1=301; L2=256; L3=1103 mm3 mm
50024 V DCα=60°; A=700; B=300; C=542; E=540; F=1000; L1=326; L2=288; L3=1103 mm3 mm
500230 V ACα=60°; A=700; B=300; C=542; E=540; F=1000; L1=326; L2=288; L3=1103 mm3 mm
56024 V DCα=60°; A=800; B=350; C=592; E=540; F=1150; L1=437; L2=357; L3=1103 mm3 mm
560230 V ACα=60°; A=800; B=350; C=592; E=540; F=1150; L1=437; L2=357; L3=1103 mm3 mm
63024 V DCα=60°; A=900; B=400; C=662; E=540; F=1300; L1=472; L2=392; L3=1103 mm3 mm
630230 V ACα=60°; A=900; B=400; C=662; E=540; F=1300; L1=472; L2=392; L3=1103 mm3 mm
Two-way distributors 45°, symmetrical, hand-operated
TW19

Two-way distributors 45°, symmetrical, hand-operated

  • The use of pneumatic actuators is recommended as they hold the inner flap better in the end position
  • Shaft and inner flap with seal

Type code: TW19. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
100α=45°; A=260; B=65; C=165; L1=117; L2=82; L3=752 mm2 mm
120α=45°; A=280; B=70; C=185; L1=127; L2=92; L3=752 mm2 mm
150α=45°; A=315; B=75; C=225; L1=142; L2=107; L3=752 mm2 mm
175α=45°; A=350; B=90; C=255; L1=151; L2=119; L3=752 mm2 mm
200α=45°; A=400; B=105; C=289; L1=164; L2=132; L3=752 mm2 mm
250α=45°; A=480; B=130; C=356; L1=205; L2=160; L3=752 mm2 mm
300α=45°; A=570; B=160; C=426; L1=230; L2=185; L3=752 mm2 mm
Two-way distributors 45°, symmetrical, fitted with pneumatic rotary actuator
TW20

Two-way distributors 45°, symmetrical, fitted with pneumatic rotary actuator

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches
  • Completely wired in limit switch box
  • Shaft and inner flap with seal
  • DN > 300 mm with welded flanges

Type code: TW20. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=45°; A=260; B=65; C=165; E=193; L1=117; L2=82; L3=2652 mm2 mm
100230 V ACα=45°; A=260; B=65; C=165; E=193; L1=117; L2=82; L3=2652 mm2 mm
12024 V DCα=45°; A=280; B=70; C=185; E=193; L1=127; L2=107; L3=2652 mm2 mm
120230 V ACα=45°; A=280; B=70; C=185; E=193; L1=127; L2=107; L3=2652 mm2 mm
15024 V DCα=45°; A=315; B=75; C=225; E=193; L1=142; L2=107; L3=2652 mm2 mm
150230 V ACα=45°; A=315; B=75; C=225; E=193; L1=142; L2=107; L3=2652 mm2 mm
17524 V DCα=45°; A=350; B=90; C=255; E=225; L1=150; L2=119; L3=2752 mm2 mm
175230 V ACα=45°; A=350; B=90; C=255; E=225; L1=150; L2=119; L3=2752 mm2 mm
20024 V DCα=45°; A=400; B=105; C=289; E=225; L1=164; L2=132; L3=3112 mm2 mm
200230 V ACα=45°; A=400; B=105; C=289; E=225; L1=164; L2=132; L3=3112 mm2 mm
25024 V DCα=45°; A=480; B=130; C=356; E=342; L1=205; L2=160; L3=3342 mm2 mm
250230 V ACα=45°; A=480; B=130; C=356; E=342; L1=205; L2=160; L3=3342 mm2 mm
30024 V DCα=45°; A=570; B=160; C=426; E=342; L1=230; L2=185; L3=3342 mm2 mm
300230 V ACα=45°; A=570; B=160; C=426; E=342; L1=230; L2=185; L3=3342 mm2 mm
35024 V DCα=45°; A=618; B=185; C=495; E=402; L1=238; L2=208; L3=3542 mm2 mm
350230 V ACα=45°; A=618; B=185; C=495; E=402; L1=238; L2=208; L3=3542 mm2 mm
40024 V DCα=45°; A=698; B=205; C=558; E=402; L1=263; L2=233; L3=3542 mm2 mm
400230 V ACα=45°; A=698; B=205; C=558; E=402; L1=263; L2=233; L3=3542 mm2 mm
45024 V DCα=45°; A=800; B=225; C=624; E=486; L1=450; L2=302; L3=3923 mm3 mm
450230 V ACα=45°; A=800; B=225; C=624; E=486; L1=450; L2=302; L3=3923 mm3 mm
50024 V DCα=45°; A=880; B=250; C=686; E=486; L1=475; L2=327; L3=3923 mm3 mm
500230 V ACα=45°; A=880; B=250; C=686; E=486; L1=475; L2=327; L3=3923 mm3 mm
Two-way distributors 45°, symmetrical, fitted with cylinder
TW21

Two-way distributors 45°, symmetrical, fitted with cylinder

  • Standard version: Right-side mounting
  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches on the cylinder
  • Shaft and inner flap with seal
  • DN > 300 mm with welded flanges

Type code: TW21. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=45°; A=260; B=65; C=165; E=440; L1=117; L2=82; L3=882 mm2 mm
100230 V ACα=45°; A=260; B=65; C=165; E=440; L1=117; L2=82; L3=882 mm2 mm
12024 V DCα=45°; A=280; B=70; C=185; E=440; L1=127; L2=92; L3=882 mm2 mm
120230 V ACα=45°; A=280; B=70; C=185; E=440; L1=127; L2=92; L3=882 mm2 mm
15024 V DCα=45°; A=315; B=75; C=225; E=470; L1=142; L2=107; L3=882 mm2 mm
150230 V ACα=45°; A=315; B=75; C=225; E=470; L1=142; L2=107; L3=882 mm2 mm
17524 V DCα=45°; A=350; B=90; C=255; E=470; L1=150; L2=119; L3=882 mm2 mm
175230 V ACα=45°; A=350; B=90; C=255; E=470; L1=150; L2=119; L3=882 mm2 mm
20024 V DCα=45°; A=400; B=105; C=289; E=470; L1=164; L2=132; L3=882 mm2 mm
200230 V ACα=45°; A=400; B=105; C=289; E=470; L1=164; L2=132; L3=882 mm2 mm
25024 V DCα=45°; A=480; B=130; C=356; E=470; L1=205; L2=160; L3=902 mm2 mm
250230 V ACα=45°; A=480; B=130; C=356; E=470; L1=205; L2=160; L3=902 mm2 mm
30024 V DCα=45°; A=570; B=160; C=426; E=470; L1=230; L2=185; L3=902 mm2 mm
300230 V ACα=45°; A=570; B=160; C=426; E=470; L1=230; L2=185; L3=902 mm2 mm
35024 V DCα=45°; A=618; B=185; C=495; E=490; L1=238; L2=208; L3=1102 mm2 mm
350230 V ACα=45°; A=618; B=185; C=495; E=490; L1=238; L2=208; L3=1102 mm2 mm
40024 V DCα=45°; A=698; B=205; C=558; E=490; L1=263; L2=233; L3=1102 mm2 mm
400230 V ACα=45°; A=698; B=205; C=558; E=490; L1=263; L2=233; L3=1102 mm2 mm
45024 V DCα=45°; A=800; B=205; C=624; E=540; L1=450; L2=302; L3=1103 mm3 mm
450230 V ACα=45°; A=800; B=205; C=624; E=540; L1=450; L2=302; L3=1103 mm3 mm
50024 V DCα=45°; A=880; B=250; C=686; E=540; L1=475; L2=327; L3=1103 mm3 mm
500230 V ACα=45°; A=880; B=250; C=686; E=540; L1=475; L2=327; L3=1103 mm3 mm
Two-way distributors 45°, asymmetrical, hand-operated
TW22

Two-way distributors 45°, asymmetrical, hand-operated

  • Standard version: Right-side mounting
  • Shaft and inner flap with seal
  • The use of pneumatic actuators is recommended as they hold the inner flap better in the end position

Type code: TW22. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
100α=45°; A=260; B=100; C=165; F=360; L1=117; L2=82; L3=752 mm2 mm
120α=45°; A=280; B=110; C=185; F=390; L1=127; L2=92; L3=752 mm2 mm
150α=45°; A=315; B=115; C=225; F=430; L1=142; L2=107; L3=752 mm2 mm
175α=45°; A=350; B=125; C=255; F=475; L1=151; L2=119; L3=752 mm2 mm
200α=45°; A=400; B=140; C=289; F=540; L1=164; L2=132; L3=752 mm2 mm
250α=45°; A=480; B=170; C=356; F=650; L1=205; L2=160; L3=752 mm2 mm
300α=45°; A=570; B=210; C=426; F=780; L1=230; L2=185; L3=752 mm2 mm
Two-way distributors 45°, asymmetrical, fitted with pneumatic rotary actuator
TW23

Two-way distributors 45°, asymmetrical, fitted with pneumatic rotary actuator

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches
  • Completely wired in limit switch box
  • Standard version: Right-side mounting
  • Shaft and inner flap with seal
  • DN > 300 mm with welded flanges

Type code: TW23. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=45°; A=260; B=100; C=165; E=193; F=360; L1=117; L2=82; L3=2652 mm2 mm
100230 V ACα=45°; A=260; B=100; C=165; E=193; F=360; L1=117; L2=82; L3=2652 mm2 mm
12024 V DCα=45°; A=280; B=110; C=185; E=193; F=390; L1=127; L2=92; L3=2652 mm2 mm
120230 V ACα=45°; A=280; B=110; C=185; E=193; F=390; L1=127; L2=92; L3=2652 mm2 mm
15024 V DCα=45°; A=315; B=115; C=225; E=193; F=430; L1=142; L2=107; L3=2652 mm2 mm
150230 V ACα=45°; A=315; B=115; C=225; E=193; F=430; L1=142; L2=107; L3=2652 mm2 mm
17524 V DCα=45°; A=350; B=125; C=255; E=225; F=475; L1=150; L2=119; L3=2752 mm2 mm
175230 V ACα=45°; A=350; B=125; C=255; E=225; F=475; L1=151; L2=119; L3=2752 mm2 mm
20024 V DCα=45°; A=400; B=140; C=289; E=225; F=540; L1=164; L2=132; L3=3112 mm2 mm
200230 V ACα=45°; A=400; B=140; C=289; E=225; F=540; L1=164; L2=132; L3=3112 mm2 mm
25024 V DCα=45°; A=480; B=170; C=356; E=342; F=650; L1=205; L2=160; L3=3342 mm2 mm
250230 V ACα=45°; A=480; B=170; C=356; E=342; F=650; L1=205; L2=160; L3=3342 mm2 mm
30024 V DCα=45°; A=570; B=210; C=426; E=342; F=780; L1=230; L2=185; L3=3342 mm2 mm
300230 V ACα=45°; A=570; B=210; C=426; E=342; F=780; L1=230; L2=185; L3=3342 mm2 mm
35024 V DCα=45°; A=618; B=230; C=495; E=402; F=848; L1=238; L2=208; L3=3542 mm2 mm
350230 V ACα=45°; A=618; B=230; C=495; E=402; F=848; L1=238; L2=208; L3=3542 mm2 mm
40024 V DCα=45°; A=698; B=250; C=558; E=402; F=948; L1=263; L2=233; L3=3542 mm2 mm
400230 V ACα=45°; A=698; B=250; C=558; E=402; F=948; L1=263; L2=233; L3=3542 mm2 mm
45024 V DCα=45°; A=800; B=270; C=624; E=486; F=1070; L1=450; L2=302; L3=3923 mm3 mm
450230 V ACα=45°; A=800; B=270; C=624; E=486; F=1070; L1=450; L2=302; L3=3923 mm3 mm
50024 V DCα=45°; A=880; B=300; C=686; E=486; F=1180; L1=475; L2=327; L3=3923 mm3 mm
500230 V ACα=45°; A=880; B=300; C=686; E=486; F=1180; L1=475; L2=327; L3=3923 mm3 mm
Two-way distributors 45°, asymmetrical, fitted with cylinder
TW24

Two-way distributors 45°, asymmetrical, fitted with cylinder

  • Control with 5/2-way solenoid valve (2-coil) and 2 limit switches on the cylinder
  • Standard version: Right-side mounting
  • Shaft and inner flap with seal
  • DN > 300 mm with welded flanges

Type code: TW24. Select the diameter, configuration and finish shown below. Send the type code and selected specification with your enquiry. A dot means availability without a stated wall thickness.

DNConfigurationDimensions (mm unless °)Wall / availability, powder-coatedWall / availability, stainless steel
10024 V DCα=45°; A=260; B=100; C=165; E=440; F=360; L1=117; L2=82; L3=882 mm2 mm
100230 V ACα=45°; A=260; B=100; C=165; E=440; F=360; L1=117; L2=82; L3=882 mm2 mm
12024 V DCα=45°; A=280; B=110; C=185; E=440; F=390; L1=127; L2=92; L3=882 mm2 mm
120230 V ACα=45°; A=280; B=110; C=185; E=440; F=390; L1=127; L2=92; L3=882 mm2 mm
15024 V DCα=45°; A=315; B=115; C=225; E=470; F=430; L1=142; L2=107; L3=882 mm2 mm
150230 V ACα=45°; A=315; B=115; C=225; E=470; F=430; L1=142; L2=107; L3=882 mm2 mm
17524 V DCα=45°; A=350; B=125; C=255; E=470; F=475; L1=150; L2=119; L3=882 mm2 mm
175230 V ACα=45°; A=350; B=125; C=255; E=470; F=475; L1=150; L2=119; L3=882 mm2 mm
20024 V DCα=45°; A=400; B=140; C=289; E=470; F=540; L1=164; L2=132; L3=882 mm2 mm
200230 V ACα=45°; A=400; B=140; C=289; E=470; F=540; L1=164; L2=132; L3=882 mm2 mm
25024 V DCα=45°; A=480; B=170; C=356; E=470; F=650; L1=205; L2=160; L3=902 mm2 mm
250230 V ACα=45°; A=480; B=170; C=356; E=470; F=650; L1=205; L2=160; L3=902 mm2 mm
30024 V DCα=45°; A=570; B=210; C=426; E=470; F=780; L1=230; L2=185; L3=902 mm2 mm
300230 V ACα=45°; A=570; B=210; C=426; E=470; F=780; L1=230; L2=185; L3=902 mm2 mm
35024 V DCα=45°; A=618; B=230; C=495; E=490; F=848; L1=238; L2=208; L3=1102 mm2 mm
350230 V ACα=45°; A=618; B=230; C=495; E=490; F=848; L1=238; L2=208; L3=1102 mm2 mm
40024 V DCα=45°; A=698; B=250; C=558; E=490; F=948; L1=263; L2=233; L3=1102 mm2 mm
400230 V ACα=45°; A=698; B=250; C=558; E=490; F=948; L1=263; L2=233; L3=1102 mm2 mm
45024 V DCα=45°; A=800; B=270; C=624; E=540; F=1070; L1=450; L2=302; L3=1103 mm3 mm
450230 V ACα=45°; A=800; B=270; C=624; E=540; F=1070; L1=450; L2=302; L3=1103 mm3 mm
50024 V DCα=45°; A=880; B=300; C=686; E=540; F=1180; L1=475; L2=327; L3=1103 mm3 mm
500230 V ACα=45°; A=880; B=300; C=686; E=540; F=1180; L1=475; L2=327; L3=1103 mm3 mm
Quote

Send SKUs, a list or a drawing

Farivo engineering team

List the SKUs and quantities, or the diameters, wall thickness and finish you need. An engineer replies on WhatsApp or email.

WhatsApp Farivo

Send your enquiry details

  • SKUs and quantities, e.g. TW01-200-20G × 12
  • Country
  • WhatsApp or email
  • Or: diameters, wall thickness, finish and what the pipes connect